beautypg.com

Starting a data terminal loopback, Aborting loopbacks, Data terminal loopback – HP 3162 User Manual

Page 89: Dtlb)

background image

Monitoring and Testing

5-25

3162-A2-GB20-40

August 2000

Starting a Data Terminal Loopback

The Data Terminal Loopback command (DTLB) loops the data received from the
selected port, for all DS0 channels allocated to the port, back out of the port. This
loopback occurs after the data passes through the port circuitry but before it
reaches the T1 framer.

496-14314-02

CSU

DSU

NETWORK

INTERFACE

DTE

(DSX-1)

ALL 1s

DTLB

DTLB

PORT 1

PORT 2

"

Procedure

To perform a Data Terminal loopback:

1. From the Main Menu screen, select Test.

2. From the Test screen, select Sync Data Port Tests.

3. In the Port field (near the top of the screen), enter either 1 or 2 depending on

the synchronous data port that you want to test.

4. For the Data Terminal Loopback command (under Local Loopbacks), select

Start.

Aborting Loopbacks

Use the Abort Tests command to stop all loopback tests or any selected loopback
test currently active on the DSU/CSU.

"

Procedure

To abort one or more loopback tests:

1. From the Main Menu screen, select Test.

2. From the Test screen, select Abort Tests.

NOTE:

To verify the abort procedure, use the System and Test Status screen in the
Status branch.