Configuration Options

C-17

3162-A2-GB20-40

August 2000

User Interface Configuration Options

The User Interface configuration options are divided into four tables as follows:

H

Communication Port Configuration Options (Table C-7)

H

External Device Configuration Options (

Table C-8

)

H

Telnet Sessions Configuration Options (

Table C-9

)

H

Ethernet Port Configuration Options (

Table C-10

)

Communication Port Configuration Options

Table C-7.

Communication Port Configuration Options (1 of 3)

Port Use: Terminal
Mgmt ASCII Terminal

Specifies how the communication port is used.

Mgmt – Configures the communication port as the link to an SNMP or Telnet system.

ASCII – Configures the communication port as an ASCII port supporting ASCII alarm
messages.

Terminal – Configures the communication port as the interface to an async terminal.

Port Type: Asynchronous
Asynchronous Synchronous

Specifies whether the communication port uses synchronous or asynchronous
operation when it is configured as the SNMP or Telnet management link.

Asynchronous – Configures the communication port for asynchronous operation.

Synchronous – Configures the communication port for synchronous operation.

NOTE:

This configuration option is not available if the Port Use configuration option
is set to ASCII or Term. In these cases, the communication port is always
asynchronous.

Clock Source: Internal
Internal External

Specifies whether the communication port uses internal or external clocking when it is
configured for synchronous operation.

Internal – Configures the communication port for internal clocking.

External – Configures the communication port for external clocking.