Table 5-1 – HP 3162 User Manual
Page 66
Monitoring and Testing
5-2
3162-A2-GB20-40
August 2000
Table 5-1.
Self-Test Results
Message
Description
Alarm Fail
The unit failed to transmit AIS or to detect an Yellow alarm.
B8ZS/LOS Fail
The unit failed to encode data properly or to detect Loss Of
Signal.
CPU Fail
The central processing unit failed internal testing.
Device Fail
One or more of the unit’s integrated circuit chips failed to pass
internal device level testing.
DSU Fail
The unit failed to internally loop data on the DSU.
DSU Port n Fail
Port’s integrated circuitry failed to pass device internal testing.
DTE T1 Fail
The unit failed to internally loop data on the DTE T1 (DSX-1)
circuit.
Failure xxxxxxxx
An 8-digit hexadecimal failure code is provided for service
personnel.
Memory Fail
The unit failed program checksum verification.
Modem fail
Unit failed to internally loop data through the modem circuit.
Network T1 Fail
The unit failed to internally loop data on the network T1 circuit.
Passed
No problems were found during power-on.
Unknown Exp Dev
The unit is not able to recognize the expansion device connected
to the main circuit card.