Table C-7.

Communication Port Configuration Options (2 of 3)

Data Rate: 9.6
1.2 2.4 4.8 9.6 14.4 19.2 38.4

Configures the bit rate for the communication port.

1.2 – Sets the bit rate to 1200 bps (for asynchronous operation only).

2.4 – Sets the bit rate to 2400 bps.

4.8 – Sets the bit rate to 4800 bps.

9.6 – Sets the bit rate to 9600 bps.

14.4 – Sets the bit rate to 14,400 bps.

19.2 – Sets the bit rate to 19,200 bps.

38.4 – Sets the bit rate to 38,400 bps.

NOTE:

This configuration option is not available if the communication port is
configured for synchronous operation and the clock source is external.

Character Length: 8
7 8

Configures the character length (7 or 8 bits) for the communication port.

NOTES: – This configuration option must be set to 8 if the communication port is

used as the network communication link.

– This configuration option is not available if the communication port is

configured for synchronous operation.

Parity: None
None Even Odd

Configures the parity (none, even, or odd) for the communication port.

NOTE:

This configuration option is not available if the communication port is
configured for synchronous operation.

Stop Bits: 1
1 1.5 2

Configures the number of stop bits (1, 1.5, or 2) for the communication port.

NOTE:

This configuration option is not available if the communication port is
configured for synchronous operation.

Ignore Control Leads: Disable
Disable DTR

Specifies whether the DSU/CSU ignores the state of the Data Terminal Ready (DTR)
input to the communication port.

Disable – The control leads are treated in the standard manner.

DTR – DTR is ignored.

NOTE:

This configuration option is not available if the communication port is
configured for synchronous operation.

Password Required: Disable
Enable Disable

Activates a password prompt that prevents access until a password is entered.

Enable – Prompts the communications port user to enter a password.