Table 5-6, For enterprise-specific traps. these, Configuration option – HP 3162 User Manual
Page 78: Table 5-7, Defines traps for each interface
Monitoring and Testing
5-14
3162-A2-GB20-40
August 2000
Table 5-6.
Enterprise-Specific Trap Definitions
Trap Value
Event
enterpriseClockFail(1)
The currently configured primary clock source has failed.
enterpriseSelfTestFail(2)
A DSU/CSU hardware failure is detected at self-test. This
trap is generated after DSU/CSU initialization.
enterpriseDeviceFail(3)
An internal DSU/CSU failure is detected by the operating
software.
enterpriseTestStart(5)
A test is initiated.
enterpriseConfigChange(6)
A configuration option is changed.
enterpriseTestClear(105)
A test is concluded.
Table 5-7.
SNMP Trap per Interface
Interface
Trap Meaning
T1 Network
Up = No alarm or test conditions.
Down = Alarm or test conditions.
DTE Drop/Insert (DSX-1)
Up = No alarm or test conditions, and the interface is
enabled.
Down = Alarm or test conditions, or the interface is
disabled.
Synchronous Data Ports
Up = No test conditions, the port is assigned to a network
interface, and both CTS and DSR are ON.
Down = Test conditions, the port is unassigned, or either
CTS or DSR is off.