Viewing the Number of Current Lamp Strikes (L/ST)
To view the number of times the fixture has attempted to strike (turn on) the current lamp:
1.
Press and hold the
2.
Using the and arrow buttons, scroll to the “INFO” menu and press the button to select the “INFO” menu.
3.
Using the and arrow buttons, scroll to the “L/ST” option and press the button to select the “L/ST” option. The LED will display the number of times the fixture has struck the current lamp.
Note
Lamp strikes are automatically reset when the lamp hours are reset (see “Resetting Lamp Hours (L/RS)” on page 3-27 below).
Viewing the Current Software Version (VER)
To view the current software version:
Using the and arrow buttons, scroll to the “VER” option and press the button to select the “VER” option. The LED will display the fixture’s current software version.
The software version is also displayed when you exit the menu system and the normal alphanumeric display cycles between displaying the software version, the fixture name, and the fixture address.
Viewing DMX Status and Construct Values (FIXT)
This menu option allows you to view DMX status and construct values for the fixture. You should follow this procedure if you are having a particular problem with a fixture; for example, a color wheel that does not respond to commands from the controller.
The following DMX status information is available for viewing:
•
BRKS - number of DMX breaks (framing errors with zero data)
FE - number of framing errors with a non-zero value (errors in data transmission)
OV - overruns (changing values could indicate data link/connector problems)
STRT - start code