Technobeam
®
User Manual
Cleaning the Internal Components
6-17
Figure 6-20. Location of the anti-reflective glass, lenses and hot mirror.
3.
If the black dim flags (located between the lens tube and the anti-
reflective glass) are closed, carefully use your fingers to open them to
clean the inside of the glass.
4.
Locate the lens tube as shown in Figure 6-21:
Figure 6-21. The lens tube contains the zoom lenses.
5.
Carefully lift the cover from the lens tube. It has two latches on each
side that secure it in place.
Anti-reflective glass
Lens tube
Hot mirror assembly
(shaded)
Focus drive screw
under lens tube (turn
to move tube for easier
access)
Lens tube
Latches (4)