beautypg.com

H step 31 – High End Systems Technobeam User Manual

Page 142

background image

Technobeam

®

User Manual

Technobeam Laser Aiming Device™

6-23

23. Make sure the fixture is oriented directly at the wall, not at an angle. If

the fixture is at an angle to the wall, it might be impossible to align the
laser properly.

24. Use the and arrow keys to navigate to the TILT option.

25. Press , then use the and arrow keys to adjust the

mirror position until the beam is round.

26. Press to accept your selection for TILT.

27. If the beam needs further adjustment, use the and arrow

keys to navigate to the PAN option.

28. Press , then use the and arrow keys to adjust the

mirror position.

29. Press to accept your selection for PAN.

30. Continue adjusting the mirror using PAN and TILT until the beam is as

round as possible.

If you cannot see the beam at all, the lamp might be off. Select LAMP
from the Test menu and make sure a value of ON is displayed; see Step
5 through Step 8.
(If the lamp still does not come on, wait a few
minutes and try again.)

31. Use the and arrow keys to navigate to the FCUS option.

32. Press , then use the and arrow keys to focus on

the edge of the beam until it is sharp.

33. Continue moving the fixture and focusing on the edge of the beam

until the beam is as round as possible, and sharply in focus.

34. When you have focused the beam, press .