2.3 Model Number Interpretation

Introduction

Write your controller’s model number in the spaces provided below and circle the corresponding
items in each table. This information will also be useful when you wire your controller.

Instructions

Select the desired key number. The arrow to the right marks the selection available.
Make the desired selections from Tables I through VI using the column below the
proper arrow.

A dot ( ) denotes availability.

Key Number

-

-

-

- _ _ _ _ _

-

_

KEY NUMBER - UDC2500 Single Loop Controller

Selection

Digital Controller for use with 90 to 264Vac Power

DC2500

Digital Controller for use with 24Vac/dc Power

DC2501

TABLE I - Specify Control Output and/or Alarms

TABLE II - Communications and Software Selections

0 _ _ _
1 _ _ _
2 _ _ _

10

Base-T

Ethernet

(Modbus RTU)

Plus Auxiliary

Output/Digital

Inputs

3 _ _ _

_ 0 _ _

_ A _ _

_ B _ _

_ L _ _

a

a

No Selection

_ _ 0 _

_ _ _ 0

_ _ _ R

0 _

C _
E _

None (Can be used as an indicator only)

Current Output (4 to 20ma, 0 to 20 ma)

Software Selections

One Alarm Relay Only

Standard Functions, Single Display
Dual Display with Auto/Manual

Set Point Programming (12 Segments) Dual Display, Auto/Manual

Limit Controller

Communications

None

Infrared interface

Auxiliary Output/Digital Inputs (1 Aux and 1 DI or 2 DI)
RS-485 Modbus Plus Auxiliary Output/Digital Inputs

None

Reserved

Output #1

_ A
_ T

Output #2 and Alarm
#1 or Alarms 1 and 2

A _

T _

R _

_ E

Open Collector Plus Alarm 1 (5 Amp Form C Relay)

_ B

Availability

Infrared Interface Included (Can be used with a Pocket PC)

_ 0

E-M Relay (5 Amp Form C) Plus Alarm 1 (5 Amp Form C Relay)

Solid State Relay (1 Amp) Plus Alarm 1 (5 Amp Form C Relay)

Electro Mechanical Relay (5 Amp Form C)
Solid State Relay (1 Amp)

No Additional Outputs or Alarms

Description

_ _

V

_ _ _ _

_ _ _ _ _ _

_ _

I

_ _ _

III

II

IV

VI

Open Collector transistor output
Dual 2 Amp Relays (Both are Form A) (Heat/Cool Applications)

DC 2500 2501

TABLE III - Input 1 can be changed in the field using external resistors

Selection

1 _ _

2 _ _
3 _ _

_ 00
_ 10

b

b

TABLE IV - Options

0 _ _ _ _
1 _ _ _ _

c

c

2 _ _ _ _

_ 0 _ _ _
_ T _ _ _
_ _ 0 _ _

_ _ _ 0 _
_ _ _ _ 0

Approvals

CE, UL and CSA (Standard)

Stainless Steel Customer ID Tag - 3 lines w/22 characters/line

None

CE, UL, CSA and FM

Tags

Future Options

None

TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA, 0-10V

Input 2

Input 1

None

None

None

TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA

0-5V, 1-5V, 0-20mA, 4-20mA

CE Only

Availability

TC, RTD, mV, 0-5V, 1-5V