beautypg.com

Cub detected ambient air errors, Table 20 cub detects ambient air error – HP 9000 V2600 SCA User Manual

Page 197

background image

Appendix A

175

LED codes

CUB detected ambient air errors

CUB detected ambient air errors

This section describes air errors detected by the monitoring utilities chip
(MUC) on the core utilities board after power-on.

Table 20

CUB detects ambient air error

LED

Fault

Symptoms

Corrective action

62

Ambient hot

1. Ambient air too hot.
2. Core utilities board (CUB) powers

down system.

3. Should have received “ambient

air too warm” error 69 prior to
this error.

• Check site temperature.
• Call the Response

Center.

63

OVERTEM
PMIB

1. MidPlane (MIB) too hot.
2. Core utilities board (CUB) sensed

overtemp on MidPlane power
board (MIBPB) and powers down
the system.

• Check that airflow is not

blocked.

• Check fans.
• Call the Response

Center.

64

QUADRL 0

1. Board overheated in Quadrant 0.
2. Core utilities board (CUB) sensed

overtemp in Quadrant 0 and
powers down the system.

Call the Response Center.

65

QUADRU 1

1. Board overheated in Quadrant 1.
2. Core utilities board (CUB) sensed

overtemp in Quadrant 1 and
powers down the system.

Call the Response Center.

66

QUADLL 2

1. Board overheated in Quadrant 2.
2. Core utilities board (CUB) sensed

overtemp in Quadrant 2 and
powers down the system.

Call the Response Center.

67

QUADLU 3

1. Board overheated in Quadrant 3.
2. Core utilities board (CUB) sensed

overtemp in Quadrant 3 and
powers down the system.

Call the Response Center.