Chapter 5

101

Configuration utilities

ccmd

If started with no options,

ccmd

disassociates itself from the terminal or

window where it was started. It instead reports to the console window
and the file /spp/data/ccmd_log.

If

ccmd

is sent a

SIGHUP

, it regenerates the database.

All scan-based operations require

ccmd

. If POST is unable to run, then

ccmd

is not able to read configuration data and some system information

is not accessible.

ccmd

works in co-operation with most utilities to share a common

ethernet port and Diagnostic (DART) bus. In general, the scan data is
sent via UDP. The DART bus should be separate from any general
purpose ethernet bus. If the DART bus is improperly set-up,

ccmd

cannot

run properly.

Since

ccmd

can become corrupted by bad data, it may be necessary to kill

the

ccmd

process to refresh the SSPs configuration image. Killing the

ccmd

process is not always enough. If the “heart beat” LED from the

SCUB is not functioning then

ccmd

is unable to communicate with the

system. A

ping

command to the SCUB will not be successful either. In

this case, the system or node must be powered down to reset the SCUB
and re-establish communication with the SSP.