Power on detected errors, Table 15 cub detects power on error – HP 9000 V2600 SCA User Manual
Page 188
166
Appendix A
LED codes
Power on detected errors
Power on detected errors
This section describes core utilities board (CUB) LED errors from
highest to lowest priority detected at power on. The Attention LED on
the core utilities board (CUB) turns on, and the Attention light bar on
the front of the node flashes to indicate the presence of an error code
listed in Table 15. Additionally, only the highest priority error is
displayed. Once remedied, an error that is cleared may expose a lesser
priority error.
Errors are listed in sequence from the highest to lowest priority.
NOTE
Errors from LED hex code 00 through hex code 67 shut the system down,
and errors from hex-code 68 through 73 leave the system up.
Table 15
CUB detects power on error
LED
Fault
Symptoms
Corrective action
00
3.3V error
(highest
priority)
1. 5V is up 3.3V is not.
2. SSP interface will not
function.
Call the Response Center.
01
ASIC Install 0
(MIB)
1. Incorrect rotation or part in
one of the processor agent
chip (PAC) sockets.
2. Incorrect rotation or part in
one of the routing (XBAR)
attachment chip (RAC)
sockets.
Call the Response Center.
02
ASIC Install 1
(EMB)
1. Incorrect rotation or part in
one of the memory access chip
(MAC) sockets.
2. Incorrect rotation or part in
one of the toroidal access chip
(TAC) on memory board (MB).
Call the Response Center.