beautypg.com

Table 15 warnings, Table 15, Warnings – Emerson Series 600T User Manual

Page 92

background image

Troubleshooting

80

Table 15 lists the warnings and some troubleshooting steps that may be taken if any of the Warnings

in appear.

If Warnings persist, contact your local Liebert representative or contact Liebert Global Services at

800-543-2378. You may also visit the Liebert Web site for information at

www.liebert.com

.

Table 15

Warnings

Warning

Label

Meaning / Possible Causes

Troubleshooting

AUXPOWER

LOW

Auxiliary power supply is low when the system is

not in OFF mode.

Factory-configurable warning

Check / Test Auxiliary power supply

VACUUM

LOW

Drag power exceeds 85W

*

Check Vitals and Vacuum History

MISER HIGH

Miser voltage is higher than 2V

Calibrate board

RUNOUT

HIGH

Runout is higher than 2.0 mil.

*

Check Vitals and Runout History

PWR SPLY

VOLT LOW

Power supply for PPMC/PCMC is lower than 21V.

Power supply for PPMC/PCMC is lower

than 21V

VIB

INOPERATIVE

VIB inoperative while enabled

Check VIB cable connections and wiring

OVERSPEED

Speed is higher than the Max Speed

Have Certified Service personnel check

software settings

SET TIME/

DATE

Time and date have not been set

Set Time/Date in Menu>View>Time/Date

* Warnings of this nature should be monitored and may be used to schedule preventive maintenance.

NOTE
A “Standby, Motor Hot” message may be displayed as a result of consecutive and repetitive

discharges. This is not a Warning but a normal operating occurrence that may occur due to

frequent charging and discharging of system. Once motor cools it will automatically resume

operation.

This manual is related to the following products: