Preliminar y – Extron Electronics MLC 104 Plus Series User Manual
Page 79

4-15
MLC 104 Plus Series • SIS Programming and Control
PRELIMINAR
Y
Command/r
esponse table for SIS commands (continued
)
Command
ASCII (T
elnet
)
(host to MLC
)
URL Encoded (W
eb
)
(host to MLC
)
Response
(MLC to host
)
Additional description
Ether
net data port configuration and use
Set global IP
port
timeout period
24
E
1*
X6(
TC
}
W1%2A
X6(
TC
|
Pti 1*
X6(
]
The global port timeout is the default
timeout period for all T
elnet sessions.
X6(
= IP
connection timeout period
specified in 10-second steps (1 - 65000,
default = 30 = 300 seconds). If no data is
received during the specified period, the
Ethernet connection closes. Responses ar
e
returned with leading zer
os.
This timeout period is applicable only when
the MLC is connected via Ethernet, and you
must be logged in as an administrator to
change this setting.
V
iew global IP
port
timeout period
E
1TC
}
W1TC
|
X6(
]
Set curr
ent port’s timeout
period
13, 24
E
0*
X6(
TC
}
W0%2A
X6(
TC
|
Pti 0*
X6(
]
The curr
ent port timeout period applies
to the curr
ently open T
elnet session only
.
When you start another T
elnet session, it
uses the default global port timeout period.
X6(
= timeout period in seconds. See
the description above. This variable is
applicable only when the MLC is connected
via Ethernet. If the MLC is connected via
RS-232 pr
otocol, only the global timeout
commands apply
, and any commands
involving
X6(
r
eturn
the
E13
err
or
response.
V
iew curr
ent port’s
timeout period
13
E
0TC
}
W0TC
|
X6(
]