MLC 104 Plus Series • SIS Programming and Control
PRELIMINAR
Y
X6#
= Pulse time in 20 ms increments. If this
parameter is missing or = 0, then pulse
length = default = 25 = 500 ms. 1 =
20 ms (minimum pulse time) to 65535 =
1310700 ms (maximum pulse time).
X6$
= Broadcast repetition interval in seconds
(0 to 255, default = 0 = off)
X6(
= IP connection timeout period specified in
10-second steps (1 - 65000, default =
30 = 300 seconds). If no data is received
during the specified period, the Ethernet
connection closes. Responses are returned
with leading zeros.
X7)
= The number to insert into an email message
if a ____.eml file has an embedded
server-side include “
” (the
E
CR
}
command
with no parameters.) The numeral is a
16-bit number to be employed as the user
defines.
This is an optional parameter. Use 0 as a
placeholder if the optional
X4&
variable is
used but
X7)
is not needed.
Maximum = 65535.
X7#
= An e-mail account username of up to 31
characters. Do not use commas. This
parameter is optional during setup and is
used for SMTP authentication.
X7$
= An e-mail account password (for SMTP
authentication) of up to 31 characters.
Do not use commas. This parameter is
optional during setup.
X7%
= An optional string for a destination email
address using the form [email protected]
X20)
= Specific input number (1 – 4)
1 = input 1 (the default after a reset)
2 = input 2
3 = input 3
4 = input 4
X20%
= Lamp hours elapsed (0 to 99999 hours)
The five-digit response includes leading
zeros. The default is 99999 hours, which
yields an “N/A” response.
X20^
= Voltage (in volts)
X20&
= Temperature in degrees Celsius (the response
is 3 digits including leading zeros)
X20*
= Display (projector) power status
0 = display power is off (default)
1 = display power is on
2 = display is powering down/off (cooling
down)
3 = display is powering up/on (warming
up)
X20(
= Front panel lockout (executive mode) status
0 = off/unlocked (default)
3 = on, disable/lock entire front panel
(buttons, volume control) and optional
connected SCP, control module(s), and IR
remote control input
X21!
= Status (in hexadecimal characters) of script
or firmware button control
.
This variable
is an 8-digit hexadecimal character
calculated from a binary bit map. It is
case-sensitive. Use capital letters. This
bit mapped number indicates whether
a button is controlled by firmware or by
X21@
= Status (in hexadecimal characters) of control
of all button lights).
This variable is an 8-digit hexadecimal
character calculated from a binary
bit map, and it is case-sensitive. Use
capital letters. This bit mapped number
indicates whether a button is controlled
by firmware or by scripts.
for details.
X21%
= IR output port number
1 = projector/display port
X21^
= Display mute or connection status
0 = off/disconnected (default for mute)
1 = on/connected
2 = unknown/unavailable (default for
connection status)
X21&
= Firmware’s event status polling period from
0 to 255 in 20 ms increments.
X21&
is
optional: if it is not set, it defaults to
100 (2 seconds) and is not shown in the
command’s response. If
X21&
is set to 0,
the firmware does not poll for event
status.
N
The event number that is polled is set by
X3%
in
the EN command.
X22#
= Digital I/O port (specifying which port)
1 = digital I/O port 1
2 = digital I/O port 2
3 = digital I/O port 3