Preliminar y – Extron Electronics MLC 104 Plus Series User Manual
Page 77

4-13
MLC 104 Plus Series • SIS Programming and Control
PRELIMINAR
Y
Command/r
esponse table for SIS commands (continued
)
Command
ASCII (T
elnet
)
(host to MLC
)
URL Encoded (W
eb
)
(host to MLC
)
Response
(MLC to host
)
Additional description
Configur
e
serial
port
parameters
24
E
X!
*
X2%
,
X2^
,
X2&
,
X2*
CP
}
Set baud rate (
X2%
), parity (
X2^
), data bits
(
X2&
), and stop bits (
X2*
) for port
X!
.
X2%
= 300, 600, 1200, 1800, 2400, 3600, 4800,
7200,
9600,
14400,
19200,
28800,
38400,
57600,
or 1
15200 baud.
X2^
= parity (only the first letter is needed):
O = odd
E = even
N = none (default)
M = mark
S = space.
X2&
= data bits: 7, 8 (default = 8).
X2*
= stop bits: 1, 2 (default = 1).
W
X!
%2A
X2%
%2C
X2^
%2C
X2&
%2C
X2*
CP
|
Cpn
X!
•Ccp
X2%
,
X2^
,
X2&
,
X2*
]
Example:
E
2*9600,N,8,1CP
}
W2%2A9600%2CN%2C8%2C1CP
|
Cpn2•Ccp9600,N,8,1
]
Set the pr
ojector contr
ol port for 9600 baud,
no parity
, 8 data bits, and 1 stop bit.
V
iew serial port parameters
E
X!
CP
}
W
X!
CP
|
X2%
,
X2^
,
X2&
,
X2(
]
Configur
e r
eceive timeout
24
E
X!
*
X1&
*
X2)
*
X2#
*
X2!
CE
}
Set the time to wait (
X1&
= waiting time in
tens of ms until r
eceipt of the first r
esponse
character befor
e terminating the r
eceive
operation,
X2)
= waiting time in
tens of ms between characters befor
e
terminating) and priority status
(
X2#
: 0 = default, use
send data string
command parameters; 1 = use
configur
e
receive timeout
command parameters)
for
port
X!
.
X2!
= #L
or
#D (see pr
evious page).
The r
esponse includes leading zer
os.
W
X
!
%2A
X1&
%2A
X2)
%2A
X2#
%2A
X2!
CE
|
Cpn
X
!
•Cce
X1
&
,
X2
)
,
X2
#
,
X2
!
]
V
iew r
eceive timeout
E
X!
CE
}
W
X
!
CE
|
X1&
,
X2)
,
X2#
,
X2!
]