Appendix B - Battery Information

Battery Location
Periodic maintenance (i.e. checking connections, cleaning, watering) on batteries is required. Lo-

cate the batteries in an accessible location to perform this maintenance. Two feet clearance above

the batteries is recommended for access to the battery terminals and removable caps (lead acid

battery types). The battery bank should be located as close to the inverter as possible without

limiting access to the inverter’s disconnects.
Battery Types
Batteries are available in different sizes, amp-hour ratings, voltage and chemistries. They are also

available for starting applications (such as an automobile starting battery) and deep discharge ap-

plications. Only the deep cycle types are recommended for inverter applications; using a starting

battery in an inverter (deep cycle) application will greatly shorten their useful life. Choose the

batteries best suited for the inverter installation and cost. Use only the same battery type for all

batteries in the bank. For best performance, all batteries should be from the same lot and date.

This information is usually printed on a label located on the battery.

Battery Temperature
Battery performance of lead-acid type batteries is greatly affected by extreme temperatures. When

a lead-acid type battery is cold, its effective amp-hour capacity is reduced. When determining

the battery requirements needed for the inverter system, realize that the battery capacity will be

reduced if they will be installed in a climate where extremely cold temperatures are expected. In

this type of environment, the batteries should be located in a heated area. At the minimum, the

batteries should be installed in an insulated enclosure; which will keep the batteries warmer as

they are being charged.
The battery bank should also be protected from high temperatures, which will shorten battery life.

In high heat situations the battery room/enclosure should be ventilated to bring in cooler air and

exhaust the hotter air. The performance of the battery bank/inverter system will substantially

increase by monitoring and preventing extreme temperatures around the batteries.
Battery Bank Sizing
The size of the battery bank determines how long the inverter will power the AC loads without

recharging. The larger the battery bank, the longer the run time. Size your battery bank to the

systems AC load requirements and length of time required to run from the batteries. In general,

the battery bank should not be discharged more than 50%. Additional DC charging devices such

as solar, wind, hydro, etc. can provide longer run times by recharging the batteries in the absence

of AC utility or generator power.

Info: For the MS-AE Series inverter/charger to perform optimally, a minimum battery

bank of 200 AH is recommended for moderate loads (<1000W) and greater than 400 AH

for heavy loads (≥1000W).

*Refrigerators, freezers and water pumps typically only run about 1/3 of the time. When adding

to the battery sizing worksheet, only list 1/3 of the total wattage rating of the appliance.

Device

(AC Load)

Wattage

Rating

Device

(AC Load)

Wattage

Rating

Blender

400 W

Coffee Maker

1200W

Computer

300 W

Color TV (19")

150 W

Drill

500 W

Hair Dryer

1000W

Hot Plate

1800 W

Iron

1000 W

Light (flo)

10 W

Light (inc)

100 W

Microwave

1000 W

Refrigerator*

500 W

Table B-1, Typical Appliance Power Consumption