Magnum Energy MS-AEJ Series User Manual
Page 10

© 2007 Magnum Energy Inc
Page 4
Introduction
16
14
15
13
Model/Serial
Number Label
AC Access
Cover
Input Circuit
Breakers
Exhaust
Air Vents
(back side)
Figure 1-3, Left Side Features
The left side of the MS-AE Series is equipped with the following features (refer to fi gure 1-3):
(13) Exhaust Air Vent - ventilation openings that allows heated air to be removed by the
internal cooling fan.
(14) Model/Serial Number Label - includes model/serial number information, date of
manufacture and inverter and charger specifi cations. See the MS-AE Specifi cations on
page 37 for more information and the different models available.
(15) AC Access Cover - provides access to the internal AC wiring terminal block. This
terminal block is used to hardwire all inverter AC input and output wiring connections. Remove
the two screws to access the AC wiring terminal block.
(16) Input circuit breakers - these circuit breakers protect the unit’s internal wiring and
pass-thru relay on each input (L1 and L2) while in the standby mode. These input circuit
breakers are not branch-circuit rated. These circuit breakers pop out when they open, press
in to reset.
CAUTION: Circuit breakers that branch-circuit rated must be installed in the inverter’s
input and output wiring.
CAUTION: The inverter’s internal AC transfer relay is rated for 30 amps per leg, the
pass-thru current must be no greater than 30 amps per leg or damage to the relays may
occur.
•
•
•
•