beautypg.com

Operation, 0 operation, 1 inverter mode – Magnum Energy MS-AEJ Series User Manual

Page 34

background image

© 2007 Magnum Energy Inc

Page 28

3.0 Operation

The MS-AE Series inverter has two normal operating routines; 1. Inverter Mode, which powers

your loads using the batteries, and 2. Standby Mode, which transfers the incoming AC Power (i.e.

utility power or a generator) to power your loads and uses this incoming power to recharge the

batteries. This inverter also includes an extensive protection circuitry to shut-down the inverter

under certain fault conditions.

3.1 Inverter Mode

When the MS-AE series is fi rst powered up, it defaults to the OFF mode.

The momentary ON/OFF

power switch (item 1 fi gure 1-1) must be lightly pressed to turn the inverter ON. Subsequently

pressing this switch alternately turns the inverter OFF and ON.
Inverter OFF - When the inverter is OFF,

no power is used from the batteries to power the AC

loads and

the status

LED will be OFF. If AC power from an external source (Utility or Generator)

is connected and qualifi ed on the inverter’s AC input, this AC input power will pass through the

inverter to power the AC loads. However, if this AC power is lost, the AC loads will no longer be

powered because the inverter is OFF.
When the inverter is turned ON, it operates either by “Searching” or “Inverting”, depending on

the connected AC loads.
Searching - When the inverter is fi rst turned ON, the automatic Search feature is enabled. This

feature is provided to conserve battery power when AC power is not required. In this mode, the

inverter pulses the AC output looking for an AC load (i.e. electrical appliance). Whenever an AC load

(greater than 5 watts) is turned on, the inverter recognizes the need for power and automatically

starts inverting. When there is no load (or less than 5 watts) detected, the inverter automatically

goes back into search mode to minimize energy consumption from the battery bank. When the

inverter is “Searching”, the inverter’s green LED fl ashes (fast).

Info: The factory default value for the Search feature is 5 watts, it can be turned off or

adjusted from 5 to 50 watts using the ME-RC remote display.

Inverting - When a load greater than 5 watts is connected to the inverter output, the MS-AE series

“inverts” the DC power from the battery and supplies 120/240VAC power to your sub-panel The

inverter’s green LED fl ashes once every 2 seconds (medium fl ash) to indicate it is inverting. The

amount of time the inverter can be inverting and

provide power is directly related to the amount

of AC loads that are connected and the capacity of the battery bank. Refer to fi gure 3-1 to see

the fl ow of power from the DC input to the AC output while in the Inverter Mode.

C B 3 (30 A )

AC H OT 2 IN

AC H OT 1 IN

AC H OT 2 OU T

AC H OT 1 OU T

D C POSIT IVE

D C N EGAT IVE

AC T ransfer R elay

Pow er T ransform er

F ET Bridge

C B 2 (30 A )

AC N EU T R AL

AC N EU T R AL

AC

D C

AC

OU T

240

VA C

120

VAC

120

VAC

D C

IN

Figure 3-1, Power Flow - Inverter Mode

Operation