© 2007 Magnum Energy Inc.

The following Magnum Energy components are available for use with the MS-AE Series inverter/

Charger. Some of these items are required depending upon the intended use of the inverter.
Automatic Generator Start (AGS) Controller

The Magnum Auto Gen Start controller is designed to automatically start your generator

based on low battery condition or high temperature.

The AGS controller includes an input voltage

jumper (for 12, 24 and 48 volt battery banks) and a 4-position DIP (Dual In-line Package) switch

which provides the ability to change the relay timing confi gurations to allow compatibility with a

wider range of generators.

Adjustable settings include battery start voltage, start temperature, run time, and “Quiet

Time” with an easy to set clock. AGS settings do not interfere with the manual start / stop opera-

tion of the generator.

Two models are available. The ME-AGS-S is the Stand-alone version for installation and

operation without an inverter; or the ME-AGS which is the Network version, allowing operation of

the AGS via the ME-RC Remote Control.
Fuse Block/Fuses

The Magnum Fuse/Fuse-block are used to protect the battery bank, inverter, and cables

from damage caused by DC short circuits and overloads. They include a slow-blow, high current

Class-T fuse with mounting block and protective cover. The fuse sizes are available in 125, 200,

300 and 400 amps.
Remote Control Display

The ME-RC Remote Control is simple to use; an easy-to-read LCD screen and “at a glance”

LEDs display complete inverter/charger status. Soft keys provide simple access to menus and a

rotary encoder knob allows you to scroll through and select a wide range of settings such as In-

verter ON/OFF, Charger ON/OFF, Shore Power Breaker Setting, AGS Control, Meter Button, Setup

and Tech menus.
Battery Monitor

The Battery Monitor Kit (ME-BMK) is a single battery bank amp-hour meter

that moni-

tors the condition of the battery and provides information to let you know how much energy you

have available and let you plan your electrical usage to ensure the battery is not being over-dis-

charged.
Remote Switch Adapters

The ME-RSA and ME-RSA-M pigtail adapters allow the inverter to be remotely switched on

and off - with or without the ME-RC remote display.
Conduit Box

The ME-CB conduit box connects to the front side of the inverter and allows conduit con-

nections when required for the AC and DC wiring.