Magnum Energy MS-AEJ Series User Manual
Page 45

Page 39
© 2007 Magnum Energy Inc.
The following Magnum Energy components are available for use with the MS-AE Series inverter/
Charger. Some of these items are required depending upon the intended use of the inverter.
Automatic Generator Start (AGS) Controller
The Magnum Auto Gen Start controller is designed to automatically start your generator
based on low battery condition or high temperature.
The AGS controller includes an input voltage
jumper (for 12, 24 and 48 volt battery banks) and a 4-position DIP (Dual In-line Package) switch
which provides the ability to change the relay timing confi gurations to allow compatibility with a
wider range of generators.
Adjustable settings include battery start voltage, start temperature, run time, and “Quiet
Time” with an easy to set clock. AGS settings do not interfere with the manual start / stop opera-
tion of the generator.
Two models are available. The ME-AGS-S is the Stand-alone version for installation and
operation without an inverter; or the ME-AGS which is the Network version, allowing operation of
the AGS via the ME-RC Remote Control.
Fuse Block/Fuses
The Magnum Fuse/Fuse-block are used to protect the battery bank, inverter, and cables
from damage caused by DC short circuits and overloads. They include a slow-blow, high current
Class-T fuse with mounting block and protective cover. The fuse sizes are available in 125, 200,
300 and 400 amps.
Remote Control Display
The ME-RC Remote Control is simple to use; an easy-to-read LCD screen and “at a glance”
LEDs display complete inverter/charger status. Soft keys provide simple access to menus and a
rotary encoder knob allows you to scroll through and select a wide range of settings such as In-
verter ON/OFF, Charger ON/OFF, Shore Power Breaker Setting, AGS Control, Meter Button, Setup
and Tech menus.
Battery Monitor
The Battery Monitor Kit (ME-BMK) is a single battery bank amp-hour meter
that moni-
tors the condition of the battery and provides information to let you know how much energy you
have available and let you plan your electrical usage to ensure the battery is not being over-dis-
charged.
Remote Switch Adapters
The ME-RSA and ME-RSA-M pigtail adapters allow the inverter to be remotely switched on
and off - with or without the ME-RC remote display.
Conduit Box
The ME-CB conduit box connects to the front side of the inverter and allows conduit con-
nections when required for the AC and DC wiring.
Appendix A -
Optional Equipment/Accessories