3.5 Start-Up

ON/OFF Switch - The inverter can be turned on and off by lightly pressing and releasing the Power

ON/OFF switch on the front of the inverter (refer to fi gure 3-5). When the inverter is fi rst connected

to the batteries, or when its automatic protection circuit has turned the inverter off, the ON/OFF

switch will need to be pressed to start the unit (or reset per section 4.1). Once the inverter has

been turned on, pressing the Power ON/OFF switch alternately turns the inverter on and off.

WARNING: The Power ON/OFF control switch does not turn on or off the charger feature.

If AC power (Utility or generator) is connected and qualifi ed on the AC input, this AC power

will also be available on the AC output and is not controlled by the Power ON/OFF switch.

Status LED Indicator - The status indicator is a green LED (Light Emitting Diode) that provides

information on the operational mode of the inverter. Watch this indicator (refer to fi gure 3-5) for

at least 10 seconds to determine the inverter’s operational condition from the information below:
Off - Indicates the inverter is off; there is no AC power (inverter, utility or generator) at the

inverter’s output terminals. If the LED says off after pressing the ON/OFF switch, there is a “fault”

condition such as low battery, high battery, overload, overtemperature or an internal fault. Refer

to the Troubleshooting section to help diagnose/clear the fault condition.
Slow fl ash (blinks on once every 8 seconds) - Indicates “fl oat” charging; and the inverter is

in Standby Mode (the external AC power that is connected to the inverters input is passing thru

the inverter and is powering the AC loads connected to the inverter’s output).
Medium fl ash (blinks on once every second):

When AC power is not connected to inverter input - Indicates the inverter is on and using

energy from the battery. The inverter is either: 1. Inverting - providing full power to the loads

connected to the inverter; or 2. Searching - conserving power and waiting for a load to be turned

on that meets or exceeds the Search Watts parameter (5 watts is the inverter default setting).

When AC power is connected to inverter input - Indicates “Absorb” charging; and the in-

verter is in Standby Mode (the external AC power that is connected to the inverters input is

passing thru the inverter and is powering the AC loads connected to the inverter’s output).

On (solid) - Indicates “bulk” charging; and the inverter is in Standby Mode (the external AC

power that is connected to the inverters input is passing thru the inverter and is powering the AC

loads connected to the inverter’s output).

Figure 3-5, Power Switch and Status Indicator

Operation

Power ON/OFF

pushbutton switch

Charging/Inverting

Status LED indicator