EN

EN

Configuration and Operation

Page 36

Operating Instructions for Powador 3200-6600_EN

Coun-

try-spec.

Settings

Menu

level

Display/

setting

Action in this menu/meaning

All countries

1

2

3

2

Date/Time

Set date and time with an additional PCB installed. (real-

time module RTC)

1

2

3

2

Clear grid-feed

meter

Allows the grid-feed meter to be cleared.

("Yield" meter and "Operating hours" meter)

"

If "yes" is selected the password is requested.

"

Setting required password number "2"

If the code number is valid, the grid-feed meter is cleared

and a confirmation is displayed with "Grid meter cleared!".

1

2

3

2

Defining total

yield

You can set the total yield to any value, for example,

when you have received a replacement unit and want to

continue the recording from the present value.

"

Select "yes" to set the total yield.

1

2

3

2

Interface

Select the RS232 or RS485 interface for data transmission

"

The interface is changed by pressing "2".

1

2

3

2

Inverter address

If the RS485 interface is active, every inverter must be

defined with a unique address. The interface is used to

communicate with the Powador-proLog.

"

By pressing key “2”, the RS485 address can be set con-

secutively from 1 to 32.

1

2

3

2

S0 interface

Selection of pulse rate for the S0 interface

500, 1000 and 2000 pulses/kWh

"

Set pulse rate.

1

2

3

2

Activate priwatt

Enables the use of the fault signal relay for the

Powador-priwatt internal consumption control relay.

"

Activate or deactivate the home feed-in function.

NOTE: Activating this option enables the Set priwatt

menu option.

1

2

3

2

Set priwatt

"

Define the switch-on power in kW that needs to be

available on an uninterrupted basis for 30 minutes

before the home feed-in is activated.

"

Define the switch-on time (operating time of Pow-

ador-priwatt after activation).

NOTE: This menu item is only available if you have

selected the “On” option for the “Activate priwatt” menu

item in the “Settings” menu.

All countries

1

2

3

2

Power Boost

Offers the option of reducing the frequency of the IGBT

bridge from 17 kHz to 9 kHz to improve efficiency.

"

Power Boost mode is activated by pressing "2".

NOTE: The change may cause operating noise.

All countries

1

2

3

2

Quick start

Menu item is displayed only when waiting for grid feed

and during ramp-up limiting.

Offers the option of ramping up the inverter faster for

inspection or testing.

If there is insufficient PV array power, the inverter stops

feeding into the grid after a short period of time.