beautypg.com

4 technical data, 1 electrical data, Technical data – KACO Powador 3200 - 6600 User Manual

Page 12: Electrical data, 4technical data

background image

EN

EN

Technical Data

Page 12

Operating Instructions for Powador 3200-6600_EN

4

Technical Data

4.1

Electrical Data

Input levels

3200

4200

4400

Max. recommended PV generator power [W]

3 200

4 200

4 400

DC MPP range from [V] to [V]

350 ... 600

Open circuit voltage [V]

800

Input current max / Isc PV [A]

8.6

11.5

12.5

Max. power per tracker [W]

3 200

4 200

4 400

Number of strings

3

Number of MPP trackers

1

Polarity safeguard

Short-circuit diode

Output levels

Rated power [VA]

2 600

3 450

3 600

Grid voltage [V]

184 - 264

Rated current [A]

11.3

15

15.6

Making current [RMS (20ms)] [A]

9.73

maximum initial residual current [A]

measured as 60ms RMS value

12.36

Rated frequency [Hz]

50/60

cos phi

0.80 inductive ... 0.80 capacitive

Number of feed-in phases

1

Distortion factor [%]

<3

General electrical data

Max. efficiency [%]

96.6

96.6

96.5

European efficiency [%]

95.8

95.8

95.9

Internal consumption: Night [W] / Standby [W]

0/11

Feed-in starts at [W]

Approx. 35

Grid monitoring

Country-specific

Circuit design

self-commutated, transformerless

Protection class

1

Transformer unit

no

Clock frequency [kHz]

17/9

CE conformity

Yes

This manual is related to the following products: