Configuration and Operation

Page 30

Operating Instructions for Powador 3200-6600_EN

8

Configuration and Operation

8.1

Controls

The inverter has a backlit LCD as well as three status LEDs. The inverter is operated using two buttons.

1
2
3

!

ok

Figure 22: LED indicators

Key

1

"Operating" LED

2

“Feed-in” LED

3

"Fault" LED

8.1.1 LED indicators

The three LEDs on the front of the inverter show the different operating states. The LEDs can display the following

states:

LED illuminated

LED flashing

LED not illuminated

Operating status

LEDs

Display

Description

Start

ok

The green “Operating” LED is on when AC voltage is

present, independent of the DC voltage.

Feed-in start

ok

Power fed into the

grid

or measured

values

The green "Operating" LED is lit.
The green "Feed-in" LED is illuminated after the coun-

try-specific waiting period*.

The inverter is ready to feed in, i.e. is on the grid.
You can hear the grid relay switch on.

Feed-in start

ok

Power fed into the

grid

or measured

values

The green "Operating" LED is lit.
The green "Grid feed" LED is illuminated after the coun-

try-specific waiting period*.

The inverter is internally power-reduced and ready to

feed in, i.e. is on the grid. (as per VDE-AR-N-4105)
Alternatives

1. Internal/external power limiting or start-up limiting

is active

2. The inverter is operating in standalone mode

Non-grid feed mode

ok

Status message

The display shows the corresponding message.

* The waiting period ensures that the generator voltage continuously remains above the power delivery limit of

200 V.