3 connecting the interfaces, Connecting the interfaces, L3 l2 l1 n pe +pv -pv +pv -pv – KACO Powador 3200 - 6600 User Manual

Page 23: Pv +pv, Danger, Installing the inverter, Authorised electrician, Figure 16: interface terminals, Taster netz

background image

EN

Installing the inverter

Page 23

Operating Instructions for Powador 3200-6600_EN

Authorised electrician

LP157F

100424

N'

L1'

N

L1

Z

1

Z

2

1

8

1

8

1

8

1

8

D8

D9

1

2

4

0

1

1

4

8

7

G
D
S

-

I

O

+

I

O

1

2

3

1

2

3

1

8

G

N

D

L3

L2 L1

N

PE

+PV

-PV

+PV

-PV

Taster

Netz-

GND

-PV

+PV

R

5

C28

C29

IC5

IC

6

IC8

IC9

C17

C18

C19

OK4

OK5

C42

C

4

5

C

4

6

C

4

7

C

4

8

R24

R25

R27

R28

R29

X

3

D17

R31

R

3

3

R35

R

3

7

R39

R41

C56

C16

R48

R60

R61

R62

R63

C58

C59

SV1

R66

R67

C65

R23

R26

R64

R65

D52

D53

D54

D55

Q1

KK5

K1

K2

CS1

CS2

PIN

T

E

M

P

+

C76

C77

C

4

3

D10

C

4

4

C

7

3

P1

P2

P3

P4

P

6

P8

P10

P11

P

1

2

P13

P

1

4

P15

C10

D4

D49

D50

D56

U5

R

7

R8

R

9

R11

P

5

D2

D37

D39

D41

R38

R40

R42

R50

D43

R56

R78

D46

D59

D

6

1

C82

C83

D67

R97

P16

P17

P18

P

1

9

R15

D831

D841

D812

C832

C842

C812

R803

R822

L861

D803

C

8

6

1

C811

C

8

2

3

C803

C804

OK821

OK881

D802

C

8

2

6

D811

D883

R831

C801

R886

C863

C803A

F2

T

R

1

D69

C96

R21

IC10

IC3

TP1

TP3

TP11

TP20

TP21

T

P

2

3

TP25

TP26

TP27

TP31

TP32

TP33

TP34

T

P

3

5

T

P

3

9

T

P

4

0

TP57

T

P

5

8

TP59

TP73

TP74

TP77

TP82

T

P

1

5

4

T

P

1

5

7

T

P

1

5

9

T

E

M

P

-

+18V

GPV

+

1

2

V

-12V

+5V

L1

L

2

VR4

VR3

C72

C55

B1

B2

SG2

SG1

SG3

S

G

4

B

4

G_V1 S_V1

G_V3

S_V3

G_V2 S_V2

G_V4

S_V4

D833

A

F

I1

R812

R885

C60

C61

C62

VR6

VR5

X

5

X

6

X4

X

7

X8

VR7

TP68

CON1

CON2

CON3

CON4

C26

C31

C36

C32

C37

C33

C38

C34

C39

C35

C30

C41

R82

R83

R

8

5

R84

VR2

VR1

R802

B801

CON5

IC801

F

8

6

1

L

B

L

1

P

C

B

1

C

O

N

6

CON7

CON8

C

O

N

9

Figure 15: DC connection of the Powador 3200-6600

Connecting the PV generator
1. Unscrew the cable fittings.
2. Remove the outer cladding of the DC cables.
3. Insert the DC leads through the cable fittings into the connection area.
4. Strip the insulation from the DC cables.
5. Connect the ends of the cables to the DC connections.
6. Check that all connected cables are securely fitted.
7. Tighten the cable fittings.
8. The requirements of protection rating IP54 are met by closing the unused cable fittings with blind caps.

»

The inverter is connected to the PV generator.

7.3

Connecting the interfaces

All interfaces are connected on the communications board located on the inner side of the doors.

DANGER

Risk of fatal injury due to electric shock
Severe injury or death may result from improper use of the interface connections and failure to

observe protection class III.

The SELV circuits (SELV: safety extra low voltage) can only be connected to other SELV circuits with

protection class III.

NOTE
When routing the interface connection cable, note that too little clearance to the DC or AC cables can

cause interference during data transfer.

K

K

K

SYM-Bus

+

+ -

-

E

V

U

S

0

CAN

CAN

B

A

RS485

Err.

max 250Vac/1A

RS232

Term

R

S

4

8

5

C

A

N

+ -

5

V

O

C

-o

u

t

+ -

CAN

L

H

10

1

2

4

0

1

2

ON

1

2

4

0

1

2

Figure 16: Interface terminals