Technical Data
Page 13
Operating Instructions for Powador 3200-6600_EN
Input levels
5300
5500
6600
Max. recommended PV generator power [W]
5 300
5 500
6 600
DC MPP range from [V] to [V]
350 ... 600
Open circuit voltage [V]
800
Input current max / Isc PV [A]
14.5
15.2
18
Max. power per tracker [W]
5 250
6 000
6 800
Number of strings
3
Number of MPP trackers
1
Polarity safeguard
Short-circuit diode
Output levels
Rated power [VA]
4 400
4 600
5 500
Grid voltage [V]
184 - 264
Rated current [A]
19.1
20
23.9
Making current [RMS (20ms)] [A]
9.73
maximum initial residual current [A]
measured as 60ms RMS value
12.36
Rated frequency [Hz]
50 / 60
cos phi
0.80 over-excited ... 0.80 under-excited
Number of feed-in phases
1
Distortion factor [%]
<3
General electrical data
Max. efficiency [%]
96.4
96.3
96.3
European efficiency [%]
95.8
95.7
95.8
Internal consumption: Night [W] / Standby [W]
0/11
Feed-in starts at [W]
Approx. 35
Grid monitoring
Country-specific
Circuit design
Self-commutated, transformerless
Protection class
1
Transformer unit
no
Clock frequency [kHz]
17/9
CE conformity
Yes
Table 2:
Electrical data