beautypg.com

Copy function related displays, Tasks, errors, and troubleshooting, Fault reset methods – Yaskawa CIMR-PUxA User Manual

Page 153: 6 copy function related displays

background image

5.6 Copy Function Related Displays

u

Tasks, Errors, and Troubleshooting

The table below lists the messages and errors that may appear when using the Copy function.
When executing the tasks offered by the Copy function, the operator will indicate the task being performed. When an error

occurs, a code appears on the operator to indicate the error. Note that errors related to the Copy function do not trigger a multi-

function output terminal that has been set up to close when a fault or alarm occurs. To clear an error, simply press any key on

the operator and the error display will disappear.

Table 5.6

lists the corrective action that can be taken when an error occurs.

Note:

1. Whenever using the copy function, the drive should be fully stopped.
2. The drive will not accept a Run command while the Copy function is being executed.
3. Parameters can only be saved to a drive when the voltage class, capacity, control mode, and software version match.

Table 5.6 Copy Function Task and Error Displays

Digital Operator Display

Task

CoPy

Writing Parameter Settings (flashing)

CPyE

Error Writing Data

CSEr

Copy Unit Error

dFPS

Drive Model Mismatch

End

Task Complete

iFEr

Communication Error

ndAT

Model, Voltage Class, Capacity Mismatch

rdEr

Error Reading Data

rEAd

Reading Parameter Settings (flashing)

vAEr

Voltage Class, Capacity Mismatch

vFyE

Parameter settings in the drive and those saved to the copy function are not the same

vrFy

Comparing Parameter Settings (flashing)

u

Fault Reset Methods

When a fault occurs, the cause of the fault must be removed and the drive must be restarted. The table below lists the different

ways to restart the drive.

After the Fault Occurs

Procedure

Fix the cause of the fault, restart the drive, and

reset the fault

Press

on the digital operator when the error code

is displayed.

LO

RE

F2

F1

ESC

RUN

STOP

ENTER

RESET

RESET

- MODE -

oC

Overcurrent

DRV

FWD

RESET

Resetting via Fault Reset Digital Input S4

Close then open the fault signal digital input via

terminal S4. S4 is set for “Fault Reset” as default

(H1-04 = 14).

Fault Reset Switch

Drive

S4 Fault Reset Digital Input

SC Digital Input Common

5.6 Copy Function Related Displays

YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide

153

5

Troubleshooting