beautypg.com

For details on the tim display – Yaskawa CIMR-PUxA User Manual

Page 143

background image

Deceleration time is too short and excessive

regenerative energy is flowing back into the

drive

• Check the load, deceleration time, and speed.
• Reduce the load inertia.
• Increase the deceleration times (C1-01 to C1-04).
• Replace the dynamic braking option with a larger device that can handle the power that is discharged.

The duty cycle is too high

Check the duty cycle. Maximum of 3% duty cycle is available when L8-01 = 1.

Excessive braking inertia

Recalculate braking load and braking power. Reduce the braking load by adjusting braking resistor

settings.

The braking operation duty cycle is too high Check the braking operation duty cycle. Braking resistor protection for ERF-type braking resistors

(L8-01 = 1) allows a braking duty cycle of maximum 3%.

The proper braking resistor has not been

installed

• Check the specifications and conditions for the braking resistor device.
• Select the optimal braking resistor.

Note:

The magnitude of the braking load trips the braking resistor overheat alarm, NOT the surface temperature. Using the braking resistor more

frequently than its rating permits will trip the alarm even when the braking resistor surface is not very hot.

Digital Operator Display

Fault Name

rr

Dynamic Braking Transistor
The built-in dynamic braking transistor failed.

Cause

Possible Solution

The braking transistor is damaged

• Cycle power to the drive and check for reoccurrence of the fault.
• Replace either the control board or the entire drive. For instructions on replacing the control board,

contact Yaskawa or a Yaskawa representative.

The control circuit is damaged

Digital Operator Display

Fault Name

SC

IGBT Short Circuit or Ground Fault

SEr

Too Many Speed Search Restarts
The number of Speed Search restarts exceeded the value set to b3-19.

Digital Operator Display

Fault Name

TdE

TdE

Time Data Error

Cause

Possible Solution

An error has occurred in the Real-Clock Time

function of the digital operator

Replace the digital operator. For instructions on replacing the digital operator, contact Yaskawa or your

nearest sales representative.

<1>

THo

Thermistor Disconnect
The thermistor that detects motor temperature has become disconnected.

<1> Detected in models 4A0930 and 4A1200.

TIE

TIE

Time Interval Error

Cause

Possible Solution

An error has occurred in the Real-Clock Time

function of the digital operator

Replace the digital operator. For instructions on replacing the digital operator, contact Yaskawa or your

nearest sales representative.

TIM

TIM

Time Not Set

Cause

Possible Solution

The Real-Time Clock for the digital operator

is not set in parameter o4-17
• The drive is a new drive, first power-up

condition

• o4-17 was set to 2, Reset, by the user,

manually clearing the Real-Time Clock

data.

Set o4-17 to 1 to set the time for the digital operator.

The drive will display the "TIM" alarm (Time Not Set) when the Real time Clock is not set . Additionally,

at power up, if the "TIM" condition is present, the drive will automatically switch to the time setting

screen (o4-17 = 1) for 30 seconds to prompt the user to set the Real-Time Clock.

The user did not set the Real Time Clock when

prompted following power-up.

Cycle power to the drive and set the Real Time Clock within 30 seconds of power-up, or set the clock

manually via parameter o4-17.

The digital operator battery is low or the

battery has been replaced

Replace the digital operator battery and set the Real-Time Clock.

An error has occurred in the Real-Time Clock

function of the digital operator

Replace the digital operator. For instructions on replacing the digital operator, contact Yaskawa or your

nearest sales representative.

5.2 Fault Detection

YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide

143

5

Troubleshooting