beautypg.com

Auto-tuning, Types of auto-tuning, Auto-tuning interruption and fault codes – Yaskawa CIMR-PUxA User Manual

Page 118: Automatic tuning sets motor parameters, 7 auto-tuning, Auto-tuning for induction motors

background image

4.7 Auto-Tuning

u

Types of Auto-Tuning

The drive offers different types of Auto-Tuning for induction motors. Refer to the tables below to select the type of Auto-

Tuning that bests suits the application.

Refer to Start-Up Flowchart on page 88

for directions on executing Auto-Tuning.

n

Auto-Tuning for Induction Motors

This feature automatically sets the V/f pattern and motor parameters E1-oo and E2-oo for an induction motor.

Table 4.29 Types of Auto-Tuning for Induction Motors

Type

Setting

Application Conditions and Benefits

Stationary Auto-Tuning for Line-to-

Line Resistance

T1-01 = 2

• The drive is used in V/f Control and other Auto-Tuning selections are not possible.
• Perform when entering motor data manually while using motor cables longer than 50

m.

• Drive and motor capacities differ.
• Tunes the drive after the cable between the drive and motor has been replaced with a

cable over 50 m long. Assumes Auto-Tuning has already been performed.

Rotational Auto-Tuning for V/f

Control

T1-01 = 3

• Recommended for applications using Speed Estimation Speed Search or using the

Energy Saving function in V/f Control.

• Assumes motor can rotate while Auto-Tuning is executed. Increases accuracy for

certain functions like torque compensation, slip compensation, Energy Saving, and

Speed Search.

Table 4.30

lists the data that must be entered for Auto-Tuning. Make sure this data is available before starting Auto-Tuning.

The necessary information is usually listed on the motor nameplate or in the motor test report provided by the motor

manufacturer.

Refer to Start-Up Flowchart on page 88

for details on the Auto-Tuning process.

Table 4.30 Auto-Tuning Input Data

Input Value

Input Parameter

Unit

Tuning Type (T1-01)

2

Line-to-Line Resistance

3

Rotational for V/f Control

Motor rated power

T1-02

kW

YES

YES

Motor rated voltage

T1-03

Vac

YES

Motor rated current

T1-04

A

YES

YES

Motor rated frequency

T1-05

Hz

YES

Number of motor poles

T1-06

-

YES

Motor rated Speed

T1-07

r/min

YES

Motor iron loss

T1-11

W

YES

u

Auto-Tuning Interruption and Fault Codes

If tuning results are abnormal or the STOP key is pressed before completion, Auto-Tuning will be interrupted and a fault code

will appear on the digital operator.

B

LO

RE

ESC

RUN

STOP

ENTER

RESET

DIGITAL OPERATOR JVOP-180

A

LO

RE

ESC

RUN

STOP

ENTER

RESET

DIGITAL OPERATOR JVOP-180

ALM

ALM

- A.TUNE -

X.XX Hz/ X.XXA

DRV

Tune Proceeding

Rdy

FWD

<

<<

<<< >>>

>>

>

- MODE -

Er-03

STOP key

DRV

FWD

RESET

A – During Auto-Tuning

B – Auto-Tuning Aborted

Figure 4.30 Auto-Tuning Aborted Display

4.7 Auto-Tuning

118

YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide