General-purpose motor and inverter motor

Induction motors are classified as general-purpose motors (limited speed range) or

inverter motors (wide speed range), based on their cooling capabilities. Therefore,
the motor overload function operates differently between these two motor types.

Example of 200V class motor

Cooling Effect

Torque Characteristics

Electronic Thermal
overload

Ge

ne

ral-

pu

rpo

s

e

Mo

to

r

Effective when operated
at 50/60Hz from
commercial power
supply

Base Frequency 60Hz

(V/f for 60Hz, 220V Input Voltage)

For low-speed operation, torque must be
limited in order to stop motor temperature
rise.

error (motor

overload protection)
occurs when
continuously operated at
50/60Hz or less at 100%
load.

In

ve

rter

Du

ty

Mo

to

r

Effective even when
operated at low speed
(approx. 6Hz)

Base Frequency 60Hz

(V/f for 60Hz, 220V Input Voltage)

Use an inverter duty motor for continuous
operation at low speed.

Electronic thermal
overload protection not
activated even when
continuously operated at
50/60Hz or less at 100%
load.