Motor Overload Protection

Electronic thermal overload relay

Instantaneous Overcurrent

Motor coasts to a stop at approx. 200% of inverter rated
current

Overload

Motor coasts to a stop after 1 minute at 150% of inverter rated
output current

Overvoltage

Motor coasts to a stop if DC bus voltage exceed 410V

Undervoltage

Stops when DC bus voltage is approx. 200V or less (approx.
160V or less for single-phase series)

Momentary Power Loss

Following items are selectable: Not provided (stops if power
loss is 15ms or longer), continuous operation if power loss is
approx. 0.5s or shorter, continuous operation

Cooling Fin Overheat

Protected by electronic circuit

Stall Prevention Level

Individual levels during accel/running, enable/disable provided
during deceleration

Cooling Fan Fault

Protected by electronic circuit (fan stalling detection)

Ground Fault

Protected by electronic circuit (rated output current level)

O

the

r F

u

n

c

ti

ons

Power Charge Indication

RUN lamp stays ON or digital operator LED stays ON.
(Charge LED is provided for 400V)
ON until the DC bus voltage becomes 50V or less.

In

pu

t

S

ign

al

s

Multi-function Input

Four of the following input signals are selectable: Reverse run
(3-wire sequence), fault reset, external fault (NO/NC contact
input), multi-step speed operation, Jog command, accel/decel
time select, external baseblock (NO/NC contact input), speed
search command, accel/decel hold command, LOCAL/
REMOTE selection, communication/control circuit terminal
selection, emergency stop fault emergency stop alarm

Ou

tpu

t S

ign

a

ls

Multi-function Output

Following output signals are selectable (1 NO/NC contact
output):
Fault, running, zero speed, at frequency, frequency detection
(output frequency

or

set value), during over torque

detection, minor error, during baseblock, operation mode,
inverter run ready, during fault retry, during UV, during speed
search, during speed search, data output through
communication

Standard Functions

Full-range automatic torque boost, slip compensation, DC
injection braking current/time at start/stop frequency reference
bias/gain, [MEMOBUS communications (RS-485/422, max.
19.2K bps).]

Voltage Class

200V single- / 3-phase

Model

CIMR-J7AU!!!!

3-phase

20P1

20P2

20P4

20P7

21P5

22P2

23P7

Single-phase

B0P1

B0P2

B0P4

B0P7

B1P5

-

-