Using output signals (n40) – Yaskawa VS mini J7 Series User Manual
Page 87

87
•
Communication/multi-function input terminal selection input (setting: 18)
(This function is effective when option card is installed)
Operation can be changed from communication command, or from multi-function
input terminal or digital operator command.
Run command and frequency reference from communication options are effective
when multi-function input terminal for this setting is “closed.”
Run command and frequency reference in LOCAL/REMOTE mode are effective
when “Open.”
Multi-function output terminal MA and MB functions can be changed when necessary
by setting parameter n40.
•
Terminal MA and MB functions: Set to n40
Using output signals (n40)
Setting
Name
Description
Ref page
0
Fault
Closed when inverter fault occurs.
–
1
Inverter Run
Closed when either FWD/REV command is input or
voltage is output from the inverter.
–
2
Agreed frequency
Closed when setting frequency agrees with inverter
output frequency.
88
3
Zero speed
Closed when inverter output frequency is less than
minimum output frequency.
–
4
Frequency detection
Output frequency
≥
frequency detection level (n58)
74
5
Frequency detection
Output frequency
≤
frequency detection level (n58)
74
6
Overtorque detection
(NO contact output)
—
73
7
Overtorque detection
(NC contact output)
—
73
10
Minor Fault
Closed when the alarm is indicated.
–
11
Base blocked
Closed when the inverter output is shut off.
–
12
Operation mode
Closed when “LOCAL” is selected by LOCAL/REMOTE
selection.
–
13
Inverter ready
Closed when inverter fault is not detected, and
operation is ready.
–
14
Fault restart
Closed during fault retry
–
15
In UV
Closed when undervoltage is detected.
–
16
In reverse run
Closed during reverse run.
–
17
In speed search
Closed when inverter conducts speed search.
–
18
Data output from
communication
Operates multi-function output terminal independently
from inverter operation (by MEMOBUS
communication).
–