Status Indicator LED
RUN and ALARM provided as standard LED’s
Digital Operator
(JVOP-140)
Available to monitor frequency reference, output frequency,
output current. 3 character, 7 segment LED Display.
Terminals
Main circuit: screw terminals
Control circuit: plug-in screw terminal
Wiring Distance between
Inverter and Motor
328ft (100m) or less‡
Enclosure
Open chassis
Cooling Method
Cooling fan is provided for 200V, 0.75kW (3-phase), 400V,
1.5kW (single-phase), others are self-cooling
E
n
vi
ron
m
e
n
ta
l
Co
nd
itio
ns
Ambient Temperature
Open chassis: -10 to +50
°
C (14 to 122
°
F)
(not frozen)
Humidity
95% RH or less (non-condensing)
Storage Temperature†
-4 to 140
°
F (-20 to +60
°
C)
Location
Indoor (free from corrosive gases or dust)
Elevation
3280ft (1000m) or less
Vibration
Up to 9.8m / S
2
(1G) at less than 20Hz, up to 2m / S
2
(0.2G) at
less than 20 to 50Hz
†Temperature during shipping (for short period)
‡ If the wiring distance between inverter and motor is long, reduce the inverter carrier frequency.
For details, refer to “Reducing motor noise or leakage current (n46)”on page 79.
Voltage Class
200V single- / 3-phase
Model
CIMR-J7AU!!!!
3-phase
20P1
20P2
20P4
20P7
21P5
22P2
23P7
Single-phase
B0P1
B0P2
B0P4
B0P7
B1P5
-
-