Selecting v/f pattern, Adjusting torque according to application – Yaskawa VS mini J7 Series User Manual
Page 58

58
• Selecting V/f pattern
Adjust motor torque by using “V/f pattern” and “full-range automatic torque boost”.
•
V/f pattern setting
Set V/f pattern by parameters n09 to n15 as described below. Set each pattern when
using a special motor (high-speed motor, etc.) or when requiring special torque
adjustment of machine.
Be sure to satisfy the following conditions for
the setting of n09 to n15.
n14 < n12 < n11 < n09
If n14 = n12, the set value of n13 is disabled.
Adjusting torque according to application
Parameters
No.
Name
Unit
Setting range
Initial Setting
n09
Max. output frequency
0.1Hz
50.0 to 400Hz
60.0Hz
n10
Max. voltage
1V
1 to 255V
(0.1 to 510V)
230V
(460V)
n11
Max. voltage output frequency
(base frequency)
0.1Hz
0.2 to 400Hz
60.0Hz
n12
Mid. output frequency
0.1Hz
0.1 to 399Hz
1.5Hz
n13
Mid. output frequency voltage
1V
0.1 to 255V
(0.1 to 510V)
12V
(24V)
n14
Min. output frequency
0.1Hz
0.1 to 10.0Hz
1.5Hz
n15
Min. output frequency voltage
1V
1 to 50V
(0.1 to 100V)
12V
(24V)
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 USB Copy Unit (2 pages)
- JVOP-181 (22 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)