beautypg.com

4 torques of ac field plugs – SMA SB 240 User Manual

Page 71

background image

Climatic Conditions

As per IEC 60721-3-4, installation type C, class 4K1

Extended temperature range

−40°C to +45°C

Extended humidity range

0% to 100%

Extended air pressure range

79.5 kPa to 106 kPa

As per IEC 60721-3-4, transport type E, class 2K3

Temperature range

−25°C to +70°C

Features

Power-line communication to inverters

As standard

Speedwire/Webconnect communication to
SMA communication products, RJ45

As standard

Display of the PV system and communication sta-
tus

2 LEDs

Torques

Screw terminals

0.6 Nm

Data Storage Capacity

Energy yield over the day per inverter

At least 63 days

Daily yields per inverter

At least 30 years

Event messages of the Sunny Multigate for users

At least 1,024 events

Event messages of the Sunny Multigate for in-
stallers

At least 1,024 events

Event messages per inverter for users

At least 256 events

Event messages per inverter for installers

At least 256 events

14.4 Torques of AC Field Plugs

Screw in insulator

0.8 Nm

Screw connection of the AC plug enclosure, ini-
tial torque

3.3 Nm

Screw connection of the AC plug enclosure, end
torque

4.4 Nm

14 Technical Data

SMA Solar Technology AG

Installation Manual

71

SMA-SB240-IA-en-12