beautypg.com

SMA SB 240 User Manual

Page 67

background image

Maximum output current

1 A

Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
< 2%, and AC power > 50% of the rated power

≤ 3%

Maximum residual output current

1 A

AC inrush current

123 mA

Rated power frequency

50 Hz

AC power frequency

50 Hz / 60 Hz

Operating range at AC power frequency 50 Hz

45.5 Hz to 63 Hz

Operating range at AC power frequency 60 Hz

45.5 Hz to 63 Hz

Power factor at rated power

1

Feed-in phases

1

Connection phases

1

Overvoltage category with Sunny Multigate as
per IEC 60664‑1

III

Protective Devices

DC reverse polarity protection

Short-circuit diode

Grid monitoring

SMA Grid Guard 5

AC short-circuit current capability

Available

Ground fault monitoring

Insulation monitoring

Galvanic isolation

Available

General Data

Width x height x depth, without connection area

188 mm x 199 mm x 43 mm

Width x height x depth, with connection area

188 mm x 218 mm x 43 mm

Weight

1.3 kg

Climatic category in accordance with IEC
60721-3-4

4K4H

Environmental category

outdoors

Pollution degree outside the enclosure

3

Pollution degree inside the enclosure

2

Operating temperature range

−40°C to +65°C

Maximum permissible value for relative humid-
ity, non-condensing

100%

14 Technical Data

SMA Solar Technology AG

Installation Manual

67

SMA-SB240-IA-en-12