beautypg.com

14 technical data, 1 requirements for the pv modules, 2 sunny boy 240 – SMA SB 240 User Manual

Page 66

background image

14 Technical Data

14.1 Requirements for the PV Modules

Maximum DC power at standard test condition-
s (STC)

300 W

MPP voltage range at standard test condition-
s (STC)

26 V to 32 V

Maximum short-circuit current at standard test
conditions (STC)

12 A

14.2 Sunny Boy 240

DC Input

Maximum number of connected PV modules per
inverter

1

Maximum input voltage

45 V

MPP voltage range at 230 V

23.0 V to 39.0 V

Rated input voltage

29.5 V

Minimum input voltage

23.0 V

Minimum initial input voltage

23.0 V

Maximum initial input voltage

40 V

Maximum input current

8.5 A

Maximum short-circuit current per module*

12 A

Overvoltage category as per IEC 60664-1

II

* In accordance with IEC 62109-2: ISC PV

AC Output

Rated power at 230 V, 50 Hz

230 W

Maximum apparent AC power

230 VA

Rated grid voltage

230 V

Nominal AC voltage

220 V / 230 V / 240 V

AC voltage range

184 V to 270 V

Nominal AC current at 220 V

1 A

Nominal AC current at 230 V

1 A

Nominal AC current at 240 V

0.96 A

14 Technical Data

SMA Solar Technology AG

Installation Manual

SMA-SB240-IA-en-12

66