beautypg.com

3 sunny multigate – SMA SB 240 User Manual

Page 69

background image

AC connection

AC cable with two connectors**

Powerline interface

As standard

* The DC connectors supplied are dependent on the order. You can find the SMA order numbers of the

DC connectors in this document (see Section 15 "Spare Parts and Accessories", page 72).

** The length of the AC cable depends on the order and is either 1.40 m or 2.0 m.

Efficiency

Maximum efficiency, η

max

95.8%

European efficiency, η

EU

95.3%

14.3 Sunny Multigate

AC Input

Maximum number of connected micro inverters

12

Minimum number of connected micro inverters

1

Maximum input current

12 A

AC Output

Rated power at 230 V, 50 Hz

2,760 W

Rated grid voltage

230 V

Nominal AC voltage

220 V / 230 V / 240 V

AC voltage range

184 V to 270 V

Nominal AC current at 220 V

12 A

Nominal AC current at 230 V

12 A

Nominal AC current at 240 V

11.5 A

Maximum output current

12 A

Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
< 2%, and AC power > 50% of the rated power

≤ 3%

Rated power frequency

50 Hz

AC power frequency

50 Hz / 60 Hz

Operating range at AC power frequency 50 Hz

45.5 Hz to 63 Hz

Operating range at AC power frequency 60 Hz

45.5 Hz to 63 Hz

Power factor at rated power

1

Feed-in phases

1

14 Technical Data

SMA Solar Technology AG

Installation Manual

69

SMA-SB240-IA-en-12