Procedure:

• Switch on the circuit breaker.

☑ Both LEDs on the Sunny Multigate are glowing green. Feed-in operation begins.

✖ The LED Inverter is off?

There is a disturbance in the PV system.

• Eliminate the disturbance (see Section 11 "Troubleshooting", page 51). You will find the

detailed error message in Sunny Portal or Sunny Explorer.

✖ The LED Inverter on the Sunny Multigate is glowing orange or red?

There is a disturbance in at least one of the connected inverters.

• Eliminate the disturbance (see Section 11 "Troubleshooting", page 51). You will find the

detailed error message in Sunny Portal or Sunny Explorer.

✖ The LED Multigate on the Sunny Multigate is glowing orange or red?

There is a disturbance in the Sunny Multigate.

• Eliminate the disturbance (see Section 4.3 "LED Signals", page 16).

7 Commissioning the PV System

SMA Solar Technology AG

Installation Manual

43

SMA-SB240-IA-en-12