Comparison: Differences in Test Run,
functionality
Comparison: Differences in Test Run, operation
Function
TNC 640
iTNC 530
Display of delta values DR and DL from
TOOL CALL
block
Are not considered
Are considered
Test Run up to block N
Function not available
Function available
Calculation of machining time
Each time the simulation is repeated by
pressing the START soft key, the
machining time is totaled
Each time the simulation is repeated by
pressing the START soft key, time
calculation starts at 0
Function
TNC 640
iTNC 530
Arrangement of soft-key rows and soft
keys within the rows
Arrangement of soft-key rows and soft-keys varies depending on the active screen
layout.
Zoom function
Each sectional plane can be selected by
individual soft keys
Sectional plane can be selected via
three toggle soft keys
Machine-specific miscellaneous
functions M
Lead to error messages if they are not
integrated in the PLC
Are ignored during Test Run
Displaying/editing the tool table
Function available via soft key
Function not available