beautypg.com

2 t ool d a ta – HEIDENHAIN TNC 640 (34059x-01) ISO programming User Manual

Page 160

background image

160

Programming: Tools

5.2 T

ool D

a

ta

There are two ways to run a tool usage test for a pallet file:

„

The highlight is on a pallet entry in the pallet file:
The TNC runs the tool usage test for the entire pallet.

„

The highlight is on a program entry in the pallet file:
The TNC runs the tool usage test for the selected program

RAD

Tool radius R

+ Oversize of tool radius DR

from the tool table (in mm)

BLOCK

Block number in which the TOOL CALL block
was programmed

PATH

„

TOKEN

= TOOL: Path name of the active main

program or subprogram

„

TOKEN

= STOTAL: Path name of the

subprogram

T

Tool number with tool index

OVRMAX

Maximum feed rate override that occurred
during machining. During Test Run the TNC
enters the value 100 (%)

OVRMIN

Minimum feed rate override that occurred
during machining. During Test Run the TNC
enters the value –1

NAMEPROG

„

0

: The tool number is programmed

„

1

: The tool name is programmed

Column

Meaning