beautypg.com

8 d a tu m set ting with a 3-d t o uc h pr obe – HEIDENHAIN TNC 640 (34059x-01) ISO programming User Manual

Page 394

background image

394

Manual Operation and Setup

13.8 D

a

tu

m Set

ting with a 3-D T

o

uc

h Pr

obe

Finding the angle between the angle reference axis and a
workpiece edge

U

Select the probe function by pressing the PROBING

ROT soft key

U

Rotation angle: If you need the current basic rotation

later, write down the value that appears under
Rotation angle

U

Make a basic rotation with workpiece edge to be

compared (see "Compensating Workpiece
Misalignment with a 3-D Touch Probe" on page 387)

U

Press the PROBING ROT soft key to display the angle

between the angle reference axis and the workpiece
edge as the rotation angle

U

Cancel the basic rotation, or restore the previous basic

rotation

U

This is done by setting the rotation angle to the value

that you previously wrote down

To measure the angle between two workpiece edges:

U

Select the probe function by pressing the PROBING ROT soft key

U

Rotation angle: If you need the current basic rotation later, write
down the displayed rotation angle

U

Make a basic rotation with first workpiece edge (see "Compensating
Workpiece Misalignment with a 3-D Touch Probe" on page 387)

U

Probe the second edge as for a basic rotation, but do not set the
rotation angle to zero!

U

Press the PROBING ROT soft key to display the angle PA between
the workpiece edges as the rotation angle

U

Cancel the basic rotation, or restore the previous basic rotation by
setting the rotation angle to the value that you wrote down
previously

PA

–10

100

a?

a?

L?

X

Z

Y

100