8 d a tu m set ting with a 3-d t o uc h pr obe – HEIDENHAIN TNC 640 (34059x-01) ISO programming User Manual
Page 394

394
Manual Operation and Setup
13.8 D
a
tu
m Set
ting with a 3-D T
o
uc
h Pr
obe
Finding the angle between the angle reference axis and a
workpiece edge
U
Select the probe function by pressing the PROBING
ROT soft key
U
Rotation angle: If you need the current basic rotation
later, write down the value that appears under
Rotation angle
U
Make a basic rotation with workpiece edge to be
compared (see "Compensating Workpiece
Misalignment with a 3-D Touch Probe" on page 387)
U
Press the PROBING ROT soft key to display the angle
between the angle reference axis and the workpiece
edge as the rotation angle
U
Cancel the basic rotation, or restore the previous basic
rotation
U
This is done by setting the rotation angle to the value
that you previously wrote down
To measure the angle between two workpiece edges:
U
Select the probe function by pressing the PROBING ROT soft key
U
Rotation angle: If you need the current basic rotation later, write
down the displayed rotation angle
U
Make a basic rotation with first workpiece edge (see "Compensating
Workpiece Misalignment with a 3-D Touch Probe" on page 387)
U
Probe the second edge as for a basic rotation, but do not set the
rotation angle to zero!
U
Press the PROBING ROT soft key to display the angle PA between
the workpiece edges as the rotation angle
U
Cancel the basic rotation, or restore the previous basic rotation by
setting the rotation angle to the value that you wrote down
previously
PA
10
100
a?
a?
L?
X
Z
Y
100