Programming: Q Parameters

8.6 Chec

king and Changing Q

P

ar

amet

ers

You can have the Q parameters be shown in the additional status
display in the Manual, El. Handwheel, Single Block, Full Sequence and
Test Run operating modes.

U

If you are in a program run, interrupt it if required (for example, by
pressing the machine STOP button and the INTERNAL STOP soft
key). If you are in a test run, interrupt it.

U

Call the soft-key row for screen layout

U

Select the screen layout with additional status display:

In the right half of the screen, the TNC shows the
Overview

status form

U

Press the STATUS OF Q PARAM. soft key

U

Press the Q PARAMETER LIST soft key

U

The TNC opens a pop-up window in which you can

enter the desired range for display of the
Q parameters or string parameters. Multiple
Q parameters are entered separated by commas (e.g.
Q 1,2,3,4). To define display ranges, enter a hyphen
(e.g. Q 10-14).