beautypg.com

5 using the 3-d touch probe, Overview, Selecting touch probe cycles – HEIDENHAIN TNC 640 (34059x-01) ISO programming User Manual

Page 381

background image

HEIDENHAIN TNC 640

381

13.5 Using the 3-D T

o

uc

h Pr

obe

13.5 Using the 3-D Touch Probe

Overview

The following touch probe cycles are available in the Manual Operation
mode:

Selecting touch probe cycles

U

Select the Manual Operation or El. Handwheel mode of operation

U

Select the touch probe functions by pressing the

TOUCH PROBE soft key. The TNC displays additional
soft keys: see table above

U

Select the touch probe cycle by pressing the

appropriate soft key, for example PROBING ROT for
the TNC to display the associated menu

HEIDENHAIN only gives warranty for the function of the
probing cycles if HEIDENHAIN touch probes are used.

If you use probing functions in a tilted working plane, you
must set 3-D ROT to Active for the Manual Operation and
Automatic operating modes.

Function

Soft key

Page

Calibrate the effective length

Page 384

Calibrate the effective radius

Page 385

Measure a basic rotation using a line

Page 388

Set the datum in any axis

Page 389

Setting a corner as datum

Page 390

Setting a circle center as datum

Page 391

Touch probe system data
management

See User’s
Manual for
Cycles

For more information about the touch probe table, refer to
the User’s Manual for Cycle Programming.