beautypg.com

Cycle parameters – HEIDENHAIN iTNC 530 (340 49x-06) Cycle programming User Manual

Page 475

background image

HEIDENHAIN iTNC 530

475

1

8

.4 MEA

S

URE KINEMA

TICS (Cy

c

le 451, DIN/ISO: G451; Option)

Cycle parameters

U

Mode (0=Check/1=Measure)

Q406: Specify whether

the TNC should check or optimize the active
kinematics:
0: Check the active machine kinematics. The TNC
measures the kinematics in the axes you have
defined, but it does not make any changes to it. The
TNC displays the results of measurement in a
measurement log
1: Optimize the active machine kinematics. The TNC
measures the kinematics in the rotary axes you have
defined and optimizes the position of the rotary
axes of the active kinematics.
2: Optimize the active machine kinematics. The TNC
measures the kinematics in the rotary axes you have
defined and optimizes the position and
compensates the angle
of the rotary axes of the
active kinematics. The KinematicsComp option must
be enabled for Mode 2.

U

Exact calibration sphere radius

Q407: Enter the

exact radius of the calibration sphere used. Input
range 0.0001 to 99.9999

U

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF

U

Retraction height

Q408 (absolute): Input range

0.0001 to 99999.9999

„

Input 0:
Do not move to any retraction height. The TNC
moves to the next measuring position in the axis to
be measured. Not allowed for Hirth axes! The TNC
moves to the first measuring position in the series
A, then B, then C.

„

Input >0:
Retraction height in the untilted workpiece
coordinate system to which the TNC positions
before a rotary axis positioning in the spindle axis.
Also, the TNC moves the touch probe in the
working plane to the datum. The probe monitoring
is not active in this mode. Define the positioning
velocity in parameter Q253.

Example: Calibration program

4 TOOL CALL “TASTER“ Z

5 TCH PROBE 450 SAVE KINEMATICS

Q410=0

;MODE

Q409=5

;MEMORY

6 TCH PROBE 451 MEASURE KINEMATICS

Q406=1

;MODE

Q407=12.5 ;SPHERE RADIUS

Q320=0

;SETUP CLEARANCE

Q408=0

;RETR. HEIGHT

Q253=750

;F PRE-POSITIONING

Q380=0

;REFERENCE ANGLE

Q411=-90

;START ANGLE A AXIS

Q412=+90

;END ANGLE A AXIS

Q413=0

;INCID. ANGLE A AXIS

Q414=0

;MEAS. POINTS A AXIS

Q415=-90

;START ANGLE B AXIS

Q416=+90

;END ANGLE B AXIS

Q417=0

;INCID. ANGLE B AXIS

Q418=2

;MEAS. POINTS B AXIS

Q419=-90

;START ANGLE C AXIS

Q420=+90

;END ANGLE C AXIS

Q421=0

;INCID. ANGLE C AXIS

Q422=2

;MEAS. POINTS C AXIS

Q423=4

;NO. OF MEAS. POINTS

Q431=1

;PRESET

Q432=0

;BACKLASH, ANG. RANGE

This manual is related to the following products: