beautypg.com

Cycle parameters, 5 mea s uring in 3-d (cy c le 4, fcl 3 function) – HEIDENHAIN iTNC 530 (340 49x-06) Cycle programming User Manual

Page 452

background image

452

Touch Probe Cycles: Special Functions

1

7.5 MEA

S

URING IN 3-D (Cy

c

le 4, FCL 3 function)

Cycle parameters

U

Parameter number for result:

Enter the number of

the Q parameter to which you want the TNC to assign
the first coordinate (X). Input range 0 to 1999

U

Relative measuring path in X:

X component of the

direction vector defining the direction in which the
touch probe is to move. Input range: -99999.9999 to
99999.9999

U

Relative measuring path in Y:

Y component of the

direction vector defining the direction in which the
touch probe is to move. Input range: -99999.9999 to
99999.9999

U

Relative measuring path in Z:

Z component of the

direction vector defining the direction in which the
touch probe is to move. Input range: -99999.9999 to
99999.9999

U

Maximum measuring path:

Enter the maximum

distance from the starting point by which the touch
probe may move along the direction vector. Input
range: -99999.9999 to 99999.9999

U

Feed rate for measurement

: Enter the measuring

feed rate in mm/min. Input range 0 to 3000.000

U

Maximum retraction path:

Traverse path in the

direction opposite the probing direction, after the
stylus was deflected. Input range 0 to 99999.9999

U

Reference system? (0=ACT/1=REF)

: Specify whether

the result of measurement is to be saved in the actual
coordinate system (ACT, can be shifted or rotated), or
with respect to the machine coordinate system (REF).
0: Save the measurement result in the ACT system
1: Save the measurement result in the REF system

Example: NC blocks

5 TCH PROBE 4.0 MEASURING IN 3-D

6 TCH PROBE 4.1 Q1

7 TCH PROBE 4.2 IX-0.5 IY-1 IZ-1

8 TCH PROBE
4.3 DIST +45 F100 MB50 REFERENCE SYSTEM:0

This manual is related to the following products: