8

.4 MEA

S

URE KINEMA

TICS (Cy

c

le 451, DIN/ISO: G451; Option)

4

The TNC automatically measures all three axes successively in the
resolution you defined.

5

The TNC saves the measured values in the following Q
parameters:

Parameter number

Meaning

Q141

Standard deviation measured in the A axis
(–1 if axis was not measured)

Q142

Standard deviation measured in the B axis
(–1 if axis was not measured)

Q143

Standard deviation measured in the C axis
(–1 if axis was not measured)

Q144

Optimized standard deviation in the A axis
(–1 if axis was not optimized)

Q145

Optimized standard deviation in the B axis
(–1 if axis was not optimized)

Q146

Optimized standard deviation in the C axis
(–1 if axis was not optimized)