HEIDENHAIN iTNC 530 (340 49x-06) Cycle programming User Manual
Page 376
376
Touch Probe Cycles: Automatic Datum Setting
15.9 D
A
TUM FR
OM INSIDE OF CORNER (Cy
c
le 415, DIN/ISO: G415)
U
Probe in TS axis
Q381: Specify whether the TNC
should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis
U
Probe TS axis: Coord. 1st axis
Q382 (absolute):
Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 =
1. Input range –99999.9999 to 99999.9999
U
Probe TS axis: Coord. 2nd axis
Q383 (absolute):
Coordinate of the probe point in the minor axis of the
working plane at which point the datum is to be set in
the touch probe axis. Only effective if Q381 = 1. Input
range –99999.9999 to 99999.9999
U
Probe TS axis: Coord. 3rd axis Q384 (absolute):
Coordinate of the probe point in the touch probe
axis, at which point the datum is to be set in the
touch probe axis. Only effective if Q381 = 1. Input
range –99999.9999 to 99999.9999
U
New datum in TS axis
Q333 (absolute): Coordinate in
the touch probe axis at which the TNC should set the
datum. Default setting = 0. Input range: –99999.9999
to 99999.9999
Example: NC blocks
5 TCH PROBE 415 DATUM OUTSIDE CORNER
Q263=+37
;1ST POINT 1ST AXIS
Q264=+7
;1ST POINT 2ND AXIS
Q326=50
;SPACING IN 1ST AXIS
Q296=+95
;3RD POINT 1ST AXIS
Q297=+25
;3RD POINT 2ND AXIS
Q327=45
;SPACING IN 2ND AXIS
Q261=-5
;MEASURING HEIGHT
Q320=0
;SETUP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q304=0
;BASIC ROTATION
Q305=7
;NO. IN TABLE
Q331=+0
;DATUM
Q332=+0
;DATUM
Q303=+1
;MEAS. VALUE TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+85
;1ST CO. FOR TS AXIS
Q383=+50
;2ND CO. FOR TS AXIS
Q384=+0
;3RD CO. FOR TS AXIS
Q333=+1
;DATUM