HEIDENHAIN iTNC 530 (340 49x-06) Cycle programming User Manual
Page 327

HEIDENHAIN iTNC 530
327
14.3 BA
SIC R
O
T
A
TION fr
om T
w
o Holes (Cy
c
le 40
1, DIN/ISO: G40
1
)
U
Preset number in table
Q305: Enter the preset
number in the table in which the TNC is to save the
determined basic rotation. If you enter Q305=0, the
TNC automatically places the determined basic
rotation in the ROT menu of the Manual Operation
mode. The parameter has no effect if the
misalignment is to be compensated by a rotation of
the rotary table (Q402=1). In this case the
misalignment is not saved as an angular value. Input
range 0 to 2999
U
Basic rotation / alignment
Q402: Specify whether
the TNC should compensate misalignment with a
basic rotation, or by rotating the rotary table:
0: Set basic rotation
1: Rotate the rotary table
When you select rotary table, the TNC does not save
the measured misalignment, not even when you have
defined a table line in parameter Q305.
U
Set to zero after alignment
Q337: Definition of
whether the TNC should set the display of the aligned
rotary axis to zero:
0: Do not reset the display of the rotary axis to 0 after
alignment
1: Reset the display of the rotary axis to 0 after
alignment
The TNC sets the display to 0 only if you have defined
Q402=1.
Example: NC blocks
5 TCH PROBE 401 ROT OF 2 HOLES
Q268=+37
;1ST CENTER IN 1ST AXIS
Q269=+12
;1ST CENTER IN 2ND AXIS
Q270=+75
;2ND CENTER IN 1ST AXIS
Q271=+20
;2ND CENTER IN 2ND AXIS
Q261=-5
;MEASURING HEIGHT
Q260=+20
;CLEARANCE HEIGHT
Q307=0
;PRESET BASIC ROTATION
Q305=0
;NO. IN TABLE
Q402=0
;ALIGNMENT
Q337=0
;SET TO ZERO