HEIDENHAIN iTNC 530 (340 49x-06) Cycle programming User Manual
Page 429

HEIDENHAIN iTNC 530
429
16.1
0 MEA
S
URE RIDGE WIDTH (Cy
c
le 426, DIN/ISO: G426)
U
Measuring log
Q281: Definition of whether the TNC is
to create a measuring log:
0: No measuring log
1: Generate measuring log: with the standard setting
the TNC saves the log file TCHPR426.TXT in the
directory in which your measuring program is also
stored.
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.
U
PGM stop if tolerance error
Q309: Definition of
whether in the event of a violation of tolerance limits
the TNC is to interrupt the program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message
U
Tool number for monitoring
Q330: Definition of
whether the TNC is to monitor the tool (see “Tool
monitoring” on page 400). Input range: 0 to 32767.9,
alternatively tool name with max. 16 characters
0: Monitoring not active
>0: Tool number in the tool table TOOL.T
Example: NC blocks
5 TCH PROBE 426 MEASURE RIDGE WIDTH
Q263=+50
;1ST POINT 1ST AXIS
Q264=+25
;1ST POINT 2ND AXIS
Q265=+50
;2ND POINT 1ST AXIS
Q266=+85
;2ND POINT 2ND AXIS
Q272=2
;MEASURING AXIS
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q311=45
;NOMINAL LENGTH
Q288=45
;MAX. LIMIT
Q289=44.95 ;MIN. LIMIT
Q281=1
;MEASURING LOG
Q309=0
;PGM STOP IF ERROR
Q330= ;TOOL